The VF model valve positioner incorporates a manifold mounted, 4 – 20milliamp input, I/P. The VF model can be used where you require the control valve to fail in position (Fail Freeze) on loss of the 4 – 20 milliamp input signal.
The VF model valve positioner incorporates a manifold mounted, 4 – 20milliamp input, I/P. The VF model can be used where you require the control valve to fail in position (Fail Freeze) on loss of the 4 – 20 milliamp input signal.
Check back soon for updates
Modularity is the cornerstone of the entire VRC line. Upgrading or modifying any unit is simple, quick and hassel-free. Switch from pneumatic to electro-pneumatic with ease. Upgrade a positioner in the field with Limit Switches and position Transmitters easily. VRC simplifies upgrades, minimizes inventory and eases servicing like no other line on the market.
VRC corrosion resistance is unequaled. The I/P Converter and Position Feedback Transmitter are epoxy sealed and the Proximity Switches are hermetically sealed for the ultimate environmental protection. The PPA enclosure and internals exceed NEMA standards and are specifically designed for all routine and most highly corrosive applications. The PPA enclosure is inherently waterproof and carbon graphite filled to satisfy the toughest demands in both indoor and outdoor applications.
Adaptability is a key feature of the V Series. Regardless of actuator model or design, the option V Series Universal Mounting Kit allows for customized adaptation to most current industry models, sizes and styles of quarter turn actuators. The low profile design of the V Series Universal Mounting Kit insures high performance adaption to the accessory side of the actuator.
Parameter | Specification |
---|---|
Resolution | 0.25% Maximum0.10% Typical |
Repeatability | 99.75% Minimum99.90% Typical |
Hysteresis | 0.50% Maximum0.25% Typical |
Linearity | +/- 1.0% Maximum |
Gain @80 PSIG | 250 Single-Acting500 Double-Acting |
Air Consumption @80 PSIG | 0.25 SCFM Standard Flow Spool Valve0.45 Maximum Flow Spool Valve |
Temperature Range | -40° to 150°F/-40° to 65°C |
Part | Materials |
---|---|
Models VI, VX, VF | Anodized and epoxy painted aluminum |
Enclosure | PPA Composite300 Series Stainless Port RingsCover and Mounting Bolts |
Indicator Lens | LEXAN |
Internals | PPAPPS and PEEK Composites300 Series Stainless SteelNickel Plated Brass |
Spool Valve | Carpenter 70 Grade Stainless Steel |
I/P Converter (VK02) | PPA CompositeTEFLON Coated Carbon SteelNickel Plated Carbon SteelHigh Density Polyethylene DELRIN |
Signal Diaphragm/O-Rings | BUNA N |
Valve Related Controls 143 Commerce Blvd Loveland, OH 45140
Phone: 513-677-8724 Fax: 513-677-8731
Email: [email protected] [email protected] [email protected]
The VRC VI positioner has an integral I/P module that is approved for general purpose and hazardous
locations areas. The main positioner housing offers no protection for use in hazardous locations as defined by
the NEC (National Electrical Code).
For Transmitter and switch options
The use of the T1 or T2 transmitter is for use in only general purpose areas and not hazardous areas.
For limit switch requirements the S1 and S2 options can be used in accordance with the NEC (National
Electrical Code) in the following manor in hazardous locations.
The S1 and S2 switch options are simple passive sets of switches that can be used with the correct and proper
Intrinsically Safe barrier for the hazardous location. In addition, the S2 switch option is a set of hermetically
sealed glass to metal sealed switches that may be used in Division 2 areas as defined by the NEC (National
Electrical Code).
Important Note: In all Hazardous Locations insure your
installation meets all safety requirements of the NEC and
your local authority.
The VRC VI positioner has an integral I/P module that is approved for general purpose and hazardous
locations areas. The main positioner housing offers no protection for use in hazardous locations as defined by
the NEC (National Electrical Code).
For Transmitter and switch options
The use of the T1 or T2 transmitter is for use in only general purpose areas and not hazardous areas.
For limit switch requirements the S1 and S2 options can be used in accordance with the NEC (National
Electrical Code) in the following manor in hazardous locations.
The S1 and S2 switch options are simple passive sets of switches that can be used with the correct and proper
Intrinsically Safe barrier for the hazardous location. In addition, the S2 switch option is a set of hermetically
sealed glass to metal sealed switches that may be used in Division 2 areas as defined by the NEC (National
Electrical Code).
Important Note: In all Hazardous Locations insure your installation meets all safety requirements of the NEC and your local authority.